四川省特种设备检验检测协会

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;visibility:visible;">portant;overflow-wrap:break-word!important;text-indent:36px;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);visibility:visible;font-family:黑体,SimHei;">当与所服务建筑贴邻布置时,液化石油气瓶组的总容积不应大于1m3,并应采用自然气化方式供气;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;visibility:visible;">portant;overflow-wrap:break-word!important;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;visibility:visible;">瓶组用房的总出气管道上应设置紧急事故自动切断阀;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;visibility:visible;">portant;overflow-wrap:break-word!important;background-color:transparent;font-family:黑体,SimHei;visibility:visible;">瓶组用房内应设置可燃气体探测报警装置。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;visibility:visible;">

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;visibility:visible;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;visibility:visible;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);visibility:visible;">12.0.3portant;overflow-wrap:break-word!important;background-color:rgb(255,169,0);visibility:visible;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);visibility:visible;">portant;overflow-wrap:break-word!important;">地下、半地下场所内portant;overflow-wrap:break-word!important;color:rgb(0,0,0);visibility:visible;">不应使用或储存闪点低于60℃的液体、液化石油气及其他相对密度不小于0.75的可燃气体,不应敷设输送上述可燃液体或可燃气体的管道。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;visibility:visible;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;visibility:visible;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);visibility:visible;">12.0.4portant;overflow-wrap:break-word!important;">瓶装液化石油气portant;overflow-wrap:break-word!important;color:rgb(0,0,0);visibility:visible;">的使用应符合下列规定:

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;visibility:visible;">portant;overflow-wrap:break-word!important;text-indent:36px;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;visibility:visible;">在高层建筑内不应使用瓶装液化石油气;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;visibility:visible;">portant;overflow-wrap:break-word!important;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;visibility:visible;">液化石油气钢瓶应避免受到日光直射或火源、热源的直接辐射作用,与灶具的间距不应小于0.5m;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;background-color:transparent;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);background-color:transparent;text-indent:36px;">瓶装液化石油气应与其他化学危险物品portant;overflow-wrap:break-word!important;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);background-color:transparent;letter-spacing:1px;text-indent:36px;">分开存放;注:其他化学危险物品比如醇基燃料(生物油、环保油)。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;text-indent:36px;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">充装量不小于50kg的液化石油气容器应设置在所服务建筑外的单层专用房间内,并应采取防火措施;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;text-decoration-style:solid;text-decoration-color:rgb(51,51,51);font-family:黑体,SimHei;">液化石油气容器不应超量罐装,不应使用超量罐装的气瓶;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;background-color:transparent;text-indent:0em;font-family:黑体,SimHei;">不应敲打、倒置或碰撞液化石油气容器,不应倾倒残液或私自灌气。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;letter-spacing:0.578px;">

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">12.0.5存放瓶装液化石油气和使用可燃气体、可燃液体的房间,portant;overflow-wrap:break-word!important;">应防止可燃气体在室内积聚portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">注:存放瓶装液化石油气和使用可燃气体、液体的房间,包括地上房间和地下、半地下房间。portant;overflow-wrap:break-word!important;">防止可燃气体在室内积聚的措施主要为加强和保证室内通风或排风portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;">

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);letter-spacing:1px;text-indent:2em;">portant;overflow-wrap:break-word!important;">《气瓶安全技术规程》TSG23-2021

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;background-color:rgb(255,169,0);font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;">液化石油气钢瓶4年检定

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);letter-spacing:1px;text-indent:2em;">portant;overflow-wrap:break-word!important;">《燃气工程项目规范》GB55009-2021

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">6.2.1portant;overflow-wrap:break-word!important;">商业燃具或用气设备portant;overflow-wrap:break-word!important;letter-spacing:1px;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">应设置在portant;overflow-wrap:break-word!important;">通风良好、符合安全使用条件且便于维护操作的场所portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">,并应设置portant;overflow-wrap:break-word!important;letter-spacing:1px;background-color:rgb(255,169,0);">portant;overflow-wrap:break-word!important;">燃气泄漏报警和切断等安全装置portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;font-family:黑体,SimHei;">6.2.2商业燃具或用气设备不得设置在下列场所:

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;font-family:黑体,SimHei;">空调机房、通风机房、计算机房和变、配电室等设备房间;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;">portant;overflow-wrap:break-word!important;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">易燃或易爆品的仓库、有强烈腐蚀性介质等场所。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">6.2.4portant;overflow-wrap:break-word!important;">商业燃具与燃气管道的连接软管portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">应符合本规范第6.1.7条和第6.1.8条的规定。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">6.2.5portant;overflow-wrap:break-word!important;">商业燃具portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">应设置熄火保护装置。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">6.1.7当家庭用户管道或液化石油气钢瓶调压器与燃具采用软管连接时,portant;overflow-wrap:break-word!important;">应采用专用燃具连接软管portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">。portant;overflow-wrap:break-word!important;">软管的使用年限不应低于燃具的判废年限portant;overflow-wrap:break-word!important;letter-spacing:1px;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;font-family:黑体,SimHei;">6.1.8燃具连接软管不应穿越墙体、门窗、顶棚和地面,长度不应大于2.0m且不应有接头。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第二十七条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">?电器产品、portant;overflow-wrap:break-word!important;">燃气用具的产品标准,portant;overflow-wrap:break-word!important;">应当符合消防安全的要求。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">电器产品、燃气用具的安装、使用及其线路、管路的设计、敷设、维护保养、检测,必须符合消防技术标准和管理规定。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第六十六条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">?电器产品、燃气用具的安装、使用及其线路、管路的设计、敷设、维护保养、检测不符合消防技术标准和管理规定的,责令限期改正;portant;overflow-wrap:break-word!important;">逾期不改正的,责令停止使用,可portant;overflow-wrap:break-word!important;">以并处一千元以上五千元以下罚款。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);text-indent:2em;letter-spacing:1px;font-family:黑体,SimHei;">第三十六条安全设备的设计、制造、安装、使用、检测、维修、改造和报废,应当符合国家标准或者行业标准。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">生产经营单位必须portant;overflow-wrap:break-word!important;">对安全设备进行经常性维护、保养,并定期检测portant;overflow-wrap:break-word!important;font-size:14px;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">,保证正常运转。维护、保养、检测应当作好记录,并由有关人员签字。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;">餐饮等行业的生产经营单位使用燃气的,应当安装可燃气体报警装置,并保障其正常使用portant;overflow-wrap:break-word!important;font-size:14px;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;border-width:0px;border-style:initial;border-color:initial;color:rgb(34,34,34);font-size:18px;text-indent:0em;line-height:1.75em;font-family:Arial,sans-serif;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">(八)餐饮等行业的生产经营单位使用燃气未安装可燃气体报警装置的。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;text-indent:2em;color:rgb(0,0,0);">5.5检定周期:仪器的检定周期一般portant;overflow-wrap:break-word!important;">不超过1年portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;text-indent:2em;color:rgb(0,0,0);">。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.1.4检测可燃气体和有毒气体时,探测器探头应靠近释放源,且在气体、蒸气易于聚集的地点。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">4.4.1明火加热炉与可燃气体释放源之间应设可燃气体探测器。探测器距加热炉炉边的水平距离portant;overflow-wrap:break-word!important;">宜为5m~10mportant;overflow-wrap:break-word!important;color:rgb(0,0,0);">。当明火加热炉与可燃气体释放源之间设有不燃烧材料实体墙时,实体墙靠近释放源的一侧应设探测器。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.2.3常用可燃气体及有毒气体探测器的选用应符合下列规定:

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">1轻质烃类可燃气体宜portant;overflow-wrap:break-word!important;">选用催化燃烧型portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">或红外气体探测器(可燃气体的检测常用催化燃烧方式的探测器);

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);">6.1.2检测比空气重的可燃气体或有毒气体时,探测器的安装高度宜距地坪(或楼地板)0.3m~0.6m;检测比空气轻的可燃气体或有毒气体时,探测器的安装高度宜在释放源上方2.0m内。portant;overflow-wrap:break-word!important;">检测比空气略重的可燃气体或有毒气体时,探测器的安装高度宜在释放源下方0.5m~1.0mportant;overflow-wrap:break-word!important;color:rgb(0,0,0);">;检测比空气略轻的可燃气体或有毒气体时,探测器的安装高度宜高出释放源0.5m~1.0m。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第一百一十八条:portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">【破坏电力设备罪、破坏易燃易爆设备罪】破坏电力、燃气或者其他易燃易爆设备,危害公共安全,尚未造成严重后果的,处三年以上十年以下有期徒刑。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第一百一十九条:portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">【破坏交通工具罪、破坏交通设施罪、破坏电力设备罪、破坏易燃易爆设备罪】破坏交通工具、交通设施、电力设备、燃气设备、易燃易爆设备,造成严重后果的,处十年以上有期徒刑、无期徒刑或者死刑。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">过失犯前款罪的,处三年以上七年以下有期徒刑portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">;情节较轻的,处三年以下有期徒刑或者拘役。

inkMacSystemFont,Arial,sans-serif;box-sizing:border-box!important;overflow-wrap:break-word!important;">

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第五条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">国务院建设主管部门负责全国的燃气管理工作。县级以上地方人民政府燃气管理部门负责本行政区域内的燃气管理工作。县级以上人民政府其他有关部门依照本条例和其他有关法律、法规的规定,在各自职责范围内负责有关燃气管理工作。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(一)擅自操作公用燃气阀门;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(二)将燃气管道作为负重支架或者接地引线;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(三)安装、使用不符合气源要求的燃气燃烧器具;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(四)擅自安装、改装、拆除户内燃气设施和燃气计量装置;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(五)在不具备安全条件的场所使用、储存燃气;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(六)盗用燃气;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(七)改变燃气用途或者转供燃气。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第三十三条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">县级以上地方人民政府燃气管理部门应当会同城乡规划等有关部门按照国家有关标准和规定划定燃气设施保护范围,并向社会公布。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">在燃气设施保护范围内,禁止从事下列危及燃气设施安全的活动:

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(一)建设占压地下燃气管线的建筑物、构筑物或者其他设施;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(二)进行爆破、取土等作业或者动用明火;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(三)倾倒、排放腐蚀性物质;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(四)放置易燃易爆危险物品或者种植深根植物;

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(五)其他危及燃气设施安全的活动。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第三十四条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">在燃气设施保护范围内,有关单位从事敷设管道、打桩、顶进、挖掘、钻探等可能影响燃气设施安全活动的,应当与燃气经营者共同制定燃气设施保护方案,并采取相应的安全保护措施。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第三十五条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">燃气经营者应当按照国家有关工程建设标准和安全生产管理的规定,设置燃气设施防腐、绝缘、防雷、降压、隔离等保护装置和安全警示标志,定期进行巡查、检测、维修和维护,确保燃气设施的安全运行。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第三十九portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">燃气管理部门应当会同有关部门制定燃气安全事故应急预案,建立燃气事故统计分析制度,定期通报事故处理结果。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">燃气经营者应当制定本单位燃气安全事故应急预案,配备应急人员和必要的应急装备、器材,并定期组织演练。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第四十条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">任何单位和个人发现燃气安全事故或者燃气安全事故隐患等情况,应当立即告知燃气经营者,或者向燃气管理部门、公安机关消防机构等有关部门和单位报告。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第四十一条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">燃气经营者应当建立健全燃气安全评估和风险管理体系,发现燃气安全事故隐患的,应当及时采取措施消除隐患。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">燃气管理部门以及其他有关部门和单位应当根据各自职责,对燃气经营、燃气使用的安全状况等进行监督检查,发现燃气安全事故隐患的,应当通知燃气经营者、燃气用户及时采取措施消除隐患;不及时消除隐患可能严重威胁公共安全的,燃气管理部门以及其他有关部门和单位应当依法采取措施,及时组织消除隐患,有关单位和个人应当予以配合。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第四十二条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">燃气安全事故发生后,燃气经营者应当立即启动本单位燃气安全事故应急预案,组织抢险、抢修。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">燃气安全事故发生后,燃气管理部门、安全生产监督管理部门和公安机关消防机构等有关部门和单位,应当根据各自职责,立即采取措施防止事故扩大,根据有关情况启动燃气安全事故应急预案。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第五十一条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">违反本条例规定,侵占、毁损、擅自拆除、移动燃气设施或者擅自改动市政燃气设施等破坏燃气设施的,由燃气管理部门责令限期改正,恢复原状或者采取其他补救措施,对单位处5万元以上10万元以下罚款,对个人处5000元以上5万元以下罚款;造成损失的,依法承担赔偿责任;构成犯罪的,依法追究刑事责任。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">违反本条例规定,毁损、覆盖、涂改、擅自拆除或者移动燃气设施安全警示标志的,由燃气管理部门责令限期改正,恢复原状,可以处5000元以下罚款。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第五十二条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">违反本条例规定,建设工程施工范围内有地下燃气管线等重要燃气设施,建设单位未会同施工单位与管道燃气经营者共同制定燃气设施保护方案,或者建设单位、施工单位未采取相应的安全保护措施的,由燃气管理部门责令改正,处1万元以上10万元以下罚款;造成损失的,依法承担赔偿责任;构成犯罪的,依法追究刑事责任。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">《高层民用建筑消防安全管理规定》

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">(应急管理部令第5号)

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;line-height:1.75em;text-indent:0em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第十七条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">高层民用建筑内燃气用具的安装使用及其管路敷设、维护保养和检测应当符合消防技术标准及管理规定。禁止违反燃气安全使用规定,擅自安装、改装、拆除燃气设备和用具。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;line-height:1.75em;text-indent:0em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">高层民用建筑使用燃气应当采用管道供气方式。禁止在高层民用建筑地下部分使用液化石油气。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">《机关、团体、企业、事业单位消防安全管理规定》

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">(公安部令第61号)

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第十八条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">单位应当按照国家有关规定,结合本单位的特点,建立健全各项消防安全制度和保障消防安全的操作规程,并公布执行。单位消防安全制度主要包括以下内容:……燃气和电气设备的检查和管理(包括防雷、防静电)……

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第四十三条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">消防安全管理情况应当包括以下内容:……(五)有关燃气、电气设备检测(包括防雷、防静电)等记录资料……

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">《消防监督检查规定》

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">(公安部令第120号)

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第十条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">对单位履行法定消防安全职责情况的监督抽查,应当根据单位的实际情况检查下列内容:

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(五)电器线路、燃气管路是否定期维护保养、检测。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">portant;overflow-wrap:break-word!important;caret-color:red;">《公共娱乐场所消防安全管理规定》

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">(公安部令第39号)

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;letter-spacing:1px;font-family:黑体,SimHei;">portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">第十三条portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;">在地下建筑内设置公共娱乐场所,除符合本规定其他条款的要求外,还应当符合下列规定:

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;text-align:justify;text-indent:0em;line-height:1.75em;">portant;overflow-wrap:break-word!important;color:rgb(63,63,63);text-shadow:none;letter-spacing:1px;font-family:黑体,SimHei;">(五)严禁使用液化石油气。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;border-width:0px;border-style:initial;border-color:initial;font-size:14px;letter-spacing:1px;color:rgb(0,0,0);">

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">本标准第4.7条、4.8条、第5章、6.2条、6.5条、7.1条、7.4条、7.9条、8.2条、9.1条、9.3条为强制性条款,其余为推荐性条款。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4基本要求

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.2餐饮服务单位应与取得本市核发燃气经营许可证的液化石油气供应企业签订供用气合同,合同中应明确划分对供气系统、气瓶和用气设备的安全管护责任。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.3餐饮服务单位对液化石油气气瓶的管理应符合下列规定:

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——餐饮服务单位应使用供气企业提供的气瓶,并应签订气瓶租赁合同。餐饮服务单位现存的自有产权的气瓶应通过供气企业在质量技术监督部门建立档案并由供气企业统一管理且应逐年淘汰,不应新增自购气瓶。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——餐饮服务单位应检查液化石油气气瓶的信息化标识(包含一维条码、二维条码和电子标签等)、气瓶注册登记代码钢印是否完好、清晰,不应使用无信息化标识的液化石油气气瓶。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.4餐饮服务单位应安排专人每天对供气系统和用气设备进行巡视和检查。每次换气后,应对供气系统与气瓶连接处进行测漏检查并记录检查结果。管护方式为托管的,受托方应按照协议对供气系统和用气设备进行检查,检查后双方应在检查记录上签字确认。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.5餐饮服务单位应在用餐场所显著位置设立燃气安全信息公示栏。公示信息内容应包括:本单位瓶装液化石油气安全负责人照片、姓名,安全承诺书,供气单位信息,安全检查记录等。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.6餐饮服务单位的安全管理和用气设备操作人员应具备必要的安全生产知识,熟悉有关的安全生产规章制度和安全操作规程,掌握燃气安全使用知识和安全操作技能。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.7餐饮服务单位不应从汽车槽车直接给气瓶充装液化石油气,不应在气瓶之间倒灌液化石油气;气瓶残液应由瓶装液化石油气供气企业回收处理,不应自行处理气瓶内的残液。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">4.8餐饮服务单位不应在用餐场所储存和使用液化石油气气瓶和气体卡式炉。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5瓶组气化间

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.1采用瓶组方式供应液化石油气的,应设置瓶组气化间,存储的气瓶总容积应在1m3以下(约8个50kg气瓶)。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.2当采用自然气化方式供气时,瓶组间可设置在与建筑物(住宅、重要公共建筑和高层民用建筑除外)外墙毗连的单层专用房间内,不应设置在地下室、半地下室、地窖等通风不良场所及建筑物内,并应符合下列要求:

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——建筑物耐火等级不应低于GB50016规定的二级标准;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——应通风良好,并设有直通室外的门,门、窗应向外开;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——与其他房间相邻的墙应为无门、无窗洞口的防火墙;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——瓶组间室温范围为0℃-40℃。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.5瓶组间和气化间内不得有暖气沟、地漏及其它地下建构筑物,地面材料应采用不发生火花的材料。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.6瓶组间和气化间内的电气设备应为防爆型,电气开关应安装在室外。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.7瓶组间和气化间应按标准的要求配备干粉灭火器,且数量不应少于2个。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">5.8瓶组间和气化间内不应设置燃气燃烧器具以及其他明火,不应堆放易燃、易爆物品,不应作为其他用途使用。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6气瓶

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.1采用瓶组气化供气方式宜选用YSP-118系列(50kg)气瓶。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.2应使用充装单位提供的合格气瓶。不应使用无检验合格标识或标签无法识别的气瓶。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.3使用的气瓶瓶体上的制造钢印标记、定期检验钢印标记和注册登记标记等各类印记、标记均应清晰可辨识,且应加装符合DB11/T949要求的标签,记录充装、配送、使用全过程的可溯源信息。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.4气瓶护罩应无焊缝断裂、无脱落;气瓶底座应无腐蚀、无变形、无破裂、无脱落;气瓶应能直立;气瓶阀的阀口应无损伤。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.5空瓶与实瓶应分区放置,并应有明显的区分标志。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">6.6气瓶应直立放置,放置点不应靠近热源和明火,不应使用明火、蒸汽、热水等热源对液化石油气气瓶加热。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7供气系统

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.1单瓶供气时,气瓶不应设置在地下室、半地下室或通风不良的场所,气瓶与燃具的净距不应小于0.5m。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.3供气管道应采用钢管,且应采用硬连接方式。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.4管道穿过建筑物墙体时,应敷设在两端密封的套管中。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.5管道系统为法兰连接的,法兰盘之间应做防静电跨接并接地。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.6气化器应是由具备相应制造许可证的厂家生产的合格产品。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.7瓶装液化石油气调压器应符合CJ50的规定,调压器应具有防止擅自改变调压器的设定状态的可靠措施,调压器应在有效使用年限内使用。瓶组供气系统应选用非家用调压器,调压器应有警示色。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">7.8当管道需要离开墙面架空敷设时,应采用管支架、管卡或吊卡固定,且应安装稳定牢固。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8用气设备

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8.1液化石油气的用气设备,应选用取得生产许可证的厂家生产的具有产品合格证、产品安装使用说明书和质量保证书、有产品标牌及有出厂日期的合格产品。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8.2设置用气设备的房间应具备良好的通风条件,人防工程和普通地下室不应使用液化石油气。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8.3设置用气设备的房间,净高度不得低于2.2m,并应配备数量不少于2个干粉灭火器并保持完好有效。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8.4用气设备前连接管宜选用金属管道硬连接方式,当局部采用软管连接时应符合下列规定:

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——使用金属软管时两端应采用螺纹连接方式;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——单瓶供气使用耐油橡胶软管时,软管的长度应控制在1.2m到2.0m之间且没有接口,软管不得穿越墙壁、顶棚、窗门等;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——瓶组供气管道到达用气场所的用气设备前使用耐油橡胶软管时,软管的长度不应超过1m;

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">——软管的使用年限应符合CJJ12的要求,出现老化、破损等现象,应立即更换。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">8.5设置用气设备的房间内不得使用其它火源。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">9安全装置

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">9.1瓶组气化间、用气设备房间内应设置液化石油气的可燃气体探测器,当设置紧急切断阀、强制排风装置,设置应符合GB50028的要求。设置可燃气体报警控制器时,应将其安装在有人值守的房间内。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">9.2可燃气体探测器应按CJJ/T146的要求设置、安装并校验。

portant;overflow-wrap:break-word!important;">portant;overflow-wrap:break-word!important;color:rgb(0,0,0);font-size:14px;letter-spacing:1px;font-family:黑体,SimHei;">9.3用餐场所内有液化石油气管道和用气设备时,用餐场所内应安装液化石油气的可燃气体探测器。

portant;overflow-wrap:break-word!important;clear:both;min-height:1em;">

THE END
1.强制性国家标准《电器电子产品有害物质限制使用要求》开始公开在工业和信息化部节能与综合利用司指导下,由中国电子技术标准化研究院牵头组织研制的强制性国家标准《电器电子产品有害物质限制使用要求》于2024年11月19日开始公开征求意见,意见反馈截止日期为2025年1月18日。详细内容请见工业和信息化部官网“意见征集”栏目下《公开征求对〈建筑装饰石材安全技术要求〉等8项强制性国https://www.cesi.cn/cesi/rohs/202411/10694.html
2.关于燃气具产品强制性国家标准实施的提示?四、《燃气用具连接用金属包覆软管》(GB44017-2024)。发布日期:2024年4月29日,实施日期:2024年8月1日。 ?五、《燃气用具连接内用橡胶复合软管》(GB44023-2024)。发布日期:2024年4月29日,实施日期:2024年8月1日。 ?根据《中华人民共和国标准化法》第二十五条规定,不符合强制性标准的产品、服务,不https://www.tl.gov.cn/openness/OpennessContent/show/1044550.html
3.电器产品燃气用具的产品标准,应当符合消防安全的要求。很多小伙伴都积极入坑,但并非那么容易上手,尤其对新手玩家不是很友好,攻略问答中常常会遇到电器产品、燃气用具的产品标准,应当符合消防安全的要求。不知如何解决,为此小编给大家收集整理电器产品、燃气用具的产品标准,应当符合消防安全的要求。解决办法,感兴趣的快来看看吧。 https://www.duote.com/tech/xxyxgl/345094.html
4.规定,电器产品燃气用具的产品标准,应当符合()。《中华人民共和国消防法》规定,电器产品、燃气用具的产品标准,应当符合()。 A国家标准或者行业标准 B安全规定 C消防安全的要求 正确答案 答案解析 略 真诚赞赏,手留余香 小额打赏 169人已赞赏https://www.examk.com/p/1431863101.html
5.电器产品燃气用具的产品标准,应当符合消防安全的要求。电器产品电器产品、燃气用具的产品标准,应当符合消防安全的要求。电器产品、燃气用具的安装、使用及其线路、管路的设计、敷设、维护保养、检测,必须符合()和管理规定。正确答案:消防技术标准 点击查看答案进入小程序搜题你可能喜欢居民住宅区的物业管理单位应当在管理范围内履行下列消防安全职责:[一]制定消防安全制度,落实消防https://m.ppkao.com/wangke/daan/a34a72a7b3384a5f9578836952c25b3f
6.新《消防法》对电器产品燃气用具的消防要求作了哪些规定?爱问知识人新《消防法》第二十七条规定:“电器产品、燃气用具的产品标准,应当符合消防安全的要求。电器产品、燃气https://iask.sina.com.cn/b/iQZslz9ge6wB.html
7.建筑构件和建筑材料的防火性能须符合什么标准建筑构件、建筑材料和室内装修、装饰材料的防火性能必须符合国家标准;没有国家标准的,必须符合行业标准。 人员密集场所室内装修、装饰,应当按照消防技术标准的要求,使用不燃、难燃材料。 第二十七条 电器产品、燃气用具的产品标准,应当符合消防安全的要求。 电器产品、燃气用具的安装、使用及其线路、管路的设计、敷设、维https://china.findlaw.cn/ask/question_jx_745407.html
8.徐汇区光启小学内容三.电气燃气安全管理制度 一、学校购置和使用的电器产品、燃气用具的质量应当符合国家规定的安全标准。电器产品、燃气用具的安装、使用和线路、管道的设计、敷设,应当符合国家有关安全技术规定。 二、学校建立安全用电制度,在现有额定的电容量范围内计划用电,严禁超负荷用电。 https://gqxx.xhedu.sh.cn/cms/data/html/doc/2010-10/29/25841/